Showing results: 946 - 960 of 2454 items found.
-
40-139-101 -
Pickering Interfaces Ltd.
The 40-139 2A Relay Series is suitable for applications requiring medium power switching with high density. Featuring 2A current capacity and voltages to 300VDC/250VAC it is useful for cost critical applications.
-
Ampstik® -
SensorLink
The Ampstik is easy to use and provides accurate information to anyone working with medium and high voltage. It gives line personnel the right answers so they have the ability to make decisions in the field.
-
Hubbell Power Systems Inc
Phasing testers are used on grounded and ungrounded alternating current systems to check high-voltage fuses, test for correct phase connections and test for the absence of high voltage on de-energized lines or apparatus.
-
33020 -
Chroma ATE Inc.
High channel density with 8 channels per card 6V-12V independently programable voltage level Max. current gang feature providing max. 4A output per card
-
ADP-278A -
Standard Electric Works Co., Ltd
• Shotgun Adapter • Material : Aluminum alloy • Dimension : 78.6(L) × 44.5(W) ×44.5(D) mm • Weight : Approx. 86.5g • Accessor for Hot Sticks and High Voltage Detectors
-
Helmut Fischer AG
Maximum safety with high voltage generation directly in the probe head and low-energy voltage according to ISO 2746Three instrument versions with different test voltage ranges:HV5: 0.8 5 kVHV20: 4 20 kVHV40: 8 40 kVIntuitive operation with menu navigation, rotary push switch and OLED displayExtensive selection of electrodesDisplay of the test voltage applied directly to the electrode Pore detection sensitivity: detection threshold settable to a voltage drop of 10, 20, 30 or 50 %Porosity detector switchable between static and dynamic thresholdBattery operation by means of a Li-ion battery with smart battery technology, a controller monitors the battery state permanently and avoids deep discharge
-
6213A IN-M -
Standard Electric Works Co., Ltd
● High contrast OLED display● Designed for viewing in the dark, for mining industry.● Wide viewing angle.● Smart microprocessor-controlled.● 2 x 16 characters, large, High Contrast, Intelligent OLED Display.● Automatically calculates Dielectric Absorption Ratio (DAR).● Automatically calculates Polarization Index (PI).● Insulation resistance; Auto-ranging on all ranges.● Ener-Save● Bar graph indicates test voltage. Rise and decay can be obeserved.● External voltage presence warning (>500Vac or Vdc)● Overload protection● Low battery indicator (real time battery voltage mearsurement)● Measures insulation time duration of the test● Better than 10% accuracy on all ranges● Auto-off
-
LVD-415 -
Standard Electric Works Co., Ltd
● No batteries required.● Every circuit is doubled.● Buzzer indicates voltage detected.● Led indicates voltage detected.● Neon scale indicates voltage.● Dual HBC fuses.● High grade fiber glass probes.● Super polished fiber glass.● High strength connecting cord.● Heavy duty rated.● Replaceable tips.● Choice of tips available.● Lightweight.● Small storage space.● Strong strength reliefs.● Double poles non-polarized.● Suitable for 45 to 70 Hz networks.● Contact detector type.● Passive circuitry.● Fiber glass 1.6mm - CU 35um PCB.● Super bright neon lights and LEDs.● Ergonomically-designed.● EN 61010-031 CAT IV 500V.
-
BTAS-16 -
JFM Engineering
The task of testing an aircraft’s Nickel-Cadmium batteries is complicated and involved because of the high number of cell voltage readings that need to be taken during testing. Taking voltage readings from all 20 cells in the typical nickle-cadmium aviation battery multiple times is laborious and error prone, but must be done to properly estimate the condition of the battery under test.
-
Analog Devices Inc.
Analog Devices high speed (> 50 MHz) current feedback op amps enable you to operate at higher speeds. Current feedback op amps traditionally have wider bandwidths and higher slew rates than voltage feedback amplifiers and do not feature a gain bandwidth restriction associated with voltage feedback op amps.
-
KAL1000 Series -
Dr. Strauss Messtechnik GmbH
The impulse calibration system KAL1000 is a modular system to perform tests on complete impulse voltage measuring systems and on digital recorders for the measurement of high impulse voltages and impulse currents. The modular design allows an optimal KAL-configuration depending on the actual application.Additional, this modularity allows to up-grade or modify and existing KAL1000 system in case of changing or additional requirements
-
Tektyte Pty. Ltd.
The Log4 USB is a circuit measurement tool which both display accurate readings of voltage, current, and power while also simultaneously logging all measurement data to a MicroSD card and/or the free dedicated PC software. The Log4 USB device is specifically designed to measure the low positive voltages of USB connected equipment with high accuracy.
-
iCT1 -
Altanova Group
iCT1 - CT/VT Test Set is the NEW and most advanced portable equipment capable to test current, voltage and combined transformers.With the low voltage method, known as "DC method", iCT1 is able to test Current Transformers with a very high saturation voltage, up to 30 kV, in a complete safety mode. Quick and easy to use tool, iCT1 allows to perform tests in one shot without changing the connection to the CT, thanks to the integrated 5-TAP Switchbox.
-
Model 821HH -
TREK, INC.
Trek's Model 821HH Infinitron Hand-Held Electrostatic Voltmeter represents the next generation of contacting precision surface voltage measuring instruments, providing input characteristics far beyond the limits of any currently available hand-held voltmeter product.The Model 821HH can easily measure the voltage level of both conductive and insulative objects and surfaces with virtually zero charge transfer to the measurement probe. This results in stable high accuracy voltage measurement capability for ESD-sensitive devices.
-
Tripp Lite
Power Conditioner adjusts under- and overvoltages to provide safe, computer-grade AC power that meets ANSI C84.1 specifications. Built-in automatic voltage regulation (AVR) offers three levels of voltage stabilization that correct undervoltages as low as 89V and overvoltages as high as 147V back to regulated 120V nominal power. Providing optimum voltage conditions not only extends the life of your equipment, but also keeps your equipment working through brownouts and prolonged overvoltage conditions.